Energy - Gauss - pH - Conductivity Calibration Services

1-Phase & 3-Phase Energy Meters, Active Power, Power Factor, Phase Angle, Gauss Meters (Magnetic Flux), pH Meters, and Conductivity Meters.

WhatsApp Lab Desk
Calibration Capability (CMC)
Energy: ± 0.16 % to 0.21 % | Gauss: ± 6.6 % | pH: ± 0.057 % | Conductivity: ± 1.61 % to 7.86 %
Primary Master Equipment
3Ø Energy Calibration Source, Multi Product Calibrator, Reference Gauss Meter & Standard Reference Magnets, Decade Resistance Box & Decade Megohm Box.
Governing Standards
IEC 62053, IS 13779, IS 14697, OIML R 46, ASTM D1125, ISO/IEC 17025:2017
Key Parameters & Applications
AC Active Energy, AC Active Power, AC Power Factor, Phase Angle, Magnetic Flux Density (Gauss), pH Potential (mV), Electrical Conductivity / Resistance.

Instruments & Parameters Covered (39)

Search or review approved measurement ranges and Calibration & Measurement Capabilities (CMC).

Instrument / Parameter Calibration Range CMC (±) Master / Method
1 Phase 2 Wire AC Active Energy (0.05 A to 10 A) [Permanent] 0.64 Wh to 2.4 kWh 0.21 % to 0.19 % 1 Phase 2 Wire, AC Active Energy @ (45 Hz to 65 Hz, 0.2 (Lead/ Lag) to UPF, 63.5 V to 240 V, 0.05 A to 10 A)
1 Phase 2 Wire AC Active Energy (10 A to 20 A) [Permanent] 0.127 kWh to 4.8 kWh 0.19 % to 0.16 % 1 Phase 2 Wire, AC Active Energy @ (45 Hz to 65 Hz, 0.2 (Lead/ Lag) to UPF, 63.5 V to 240 V, 10 A to 20 A)
1 Phase 2 Wire AC Active Power (PF: 0.2 Lead / Lag) [Permanent] 2.4 W to 960 W 1.2 % 1 Phase 2 Wire, AC Active Power @ (50 Hz, 0.2 (lead / lag), 120 V to 240 V, 0.1 A to 20 A)
1 Phase 2 Wire AC Active Power (PF: 0.5 Lead / Lag) [Permanent] 6 W to 2.4 kW 0.37 % 1 Phase 2 Wire, AC Active Power @ (50 Hz, 0.5 (lead / lag), 120 V to 240 V, 0.1 A to 20 A)
1 Phase 2 Wire AC Active Power (PF: 0.8 Lead / Lag) [Permanent] 9.6 W to 3.8 kW 0.18 % 1 Phase 2 Wire, AC Active Power @ (50 Hz, 0.8 (lead / lag), 120 V to 240 V, 0.1 A to 20 A)
1 Phase 2 Wire AC Active Power (UPF) [Permanent] 1.2 W to 4.8 kW 0.13 % 1 Phase 2 Wire, AC Active Power @ (50 Hz, 120 V to 240 V, 0.01 A to 20 A, UPF)
1 Phase 2 Wire AC Power Factor [Permanent] 0.2 (lead / Lag) to UPF 0.002 PF to 0.001 PF 1 Phase 2 Wire, AC Power Factor @ (50 Hz, 120 V to 240 V, 0.1 A to 20 A)
1 Phase 2 Wire Phase Angle [Permanent] 0° to 360° 0.008° 1 Phase 2 Wire, Phase Angle @ (50 Hz, 120 V to 240 V, 0.1 A to 20 A)
3 Phase 3 Wire AC Active Energy (0.05 A to 10 A) [Permanent] 1.10 Wh to 4.16 kWh 0.21 % to 0.19 % 3 Phase 3 Wire, AC Active Energy @ (45 Hz to 65 Hz, 0.2 (lead/ Lag) to UPF, 63.5 V to 240 V, 0.05 A to 10 A)
3 Phase 4 Wire AC Active Energy (0.05 A to 10 A) [Permanent] 1.10 Wh to 4.16 kWh 0.21 % to 0.19 % 3 Phase 4 Wire, AC Active Energy @ (45 Hz to 65 Hz, 0.2 (lead/ Lag) to UPF, 63.5 V to 240 V, 0.05 A to 10 A)
3 Phase 3 Wire AC Active Energy (10 A to 20 A) [Permanent] 0.219 kWh to 8.31 kWh 0.19 % to 0.16 % 3 Phase 3 Wire, AC Active Energy @ (45 Hz to 65 Hz, 0.2 (lead/ Lag) to UPF, 63.5 V to 240 V, 10 A to 20 A)
3 Phase 4 Wire AC Active Energy (10 A to 20 A) [Permanent] 0.219 kWh to 8.31 kWh 0.19 % to 0.16 % 3 Phase 4 Wire, AC Active Energy @ (45 Hz to 65 Hz, 0.2 (lead/ Lag) to UPF, 63.5 V to 240 V, 10 A to 20 A)
3 Phase 3 Wire AC Active Power [Permanent] 1.09 W to 8.31 kW 0.13 % to 0.25 % 3 Phase 3 Wire, AC Active Power @ (50 Hz, 0.2 lead / Lag to UPF, 63.5 V to 240 V, 0.05 A to 20 A)
3 Phase 4 Wire AC Active Power [Permanent] 1.09 W to 8.31 kW 0.13 % to 0.25 % 3 Phase 4 Wire, AC Active Power @ (50 Hz, 0.2 lead / Lag to UPF, 63.5 V to 240 V, 0.05 A to 20 A)
3 Phase 3 Wire AC Power Factor [Permanent] 0.2 (lead / Lag) to UPF 0.004 PF 3 Phase 3 Wire, AC Power Factor @ (50 Hz, 240 V, 1 A to 5 A)
3 Phase 4 Wire AC Power Factor [Permanent] 0.2 (lead / Lag) to UPF 0.004 PF 3 Phase 4 Wire, AC Power Factor @ (50 Hz, 240 V, 1 A to 5 A)
3 Phase 3 Wire Phase Angle [Permanent] 0° to 360° 0.006° 3 Phase 3 Wire, Phase Angle @ (50 Hz, 240 V, 1 A to 5 A)
3 Phase 4 Wire Phase Angle [Permanent] 0° to 360° 0.006° 3 Phase 4 Wire, Phase Angle @ (50 Hz, 240 V, 1 A to 5 A)
Conductivity Meter (0.1 µS to 475 mS) [Permanent] 20 ohm to 10 Mohm (0.1 µS to 475 mS) 1.61 % to 7.86 % Conductivity Meter - (0.1 µS to 475 mS)
Gauss Meter / Magnetometer [Permanent] 2.5 Gauss to 10000 Gauss 6.6 % Gauss Meter
pH Meter (0 to 20 pH) [Permanent] (-)440 mV to 440 mV (0 to 20 pH) 0.057 % pH Meter - (0 to 20 pH)
1 Phase 2 Wire AC Active Energy (0.05 A to 10 A) [On-Site] 0.64 Wh to 2.4 kWh 0.21 % to 0.19 % 1 Phase 2 Wire, AC Active Energy @ (45 Hz to 65 Hz, 0.2 (Lead/ Lag) to UPF, 63.5 V to 240 V, 0.05 A to 10 A)
1 Phase 2 Wire AC Active Energy (10 A to 20 A) [On-Site] 0.127 kWh to 4.8 kWh 0.19 % to 0.16 % 1 Phase 2 Wire, AC Active Energy @ (45 Hz to 65 Hz, 0.2 (Lead/ Lag) to UPF, 63.5 V to 240 V, 10 A to 20 A)
1 Phase 2 Wire AC Active Power (PF: 0.2 Lead / Lag) [On-Site] 2.4 W to 960 W 1.2 % 1 Phase 2 Wire, AC Active Power @ (50 Hz, 0.2 (lead / lag), 120 V to 240 V, 0.1 A to 20 A)
1 Phase 2 Wire AC Active Power (PF: 0.5 Lead / Lag) [On-Site] 6 W to 2.4 kW 0.37 % 1 Phase 2 Wire, AC Active Power @ (50 Hz, 0.5 (lead / lag), 120 V to 240 V, 0.1 A to 20 A)

Frequently Asked Questions

Are Energy - Gauss - pH - Conductivity calibrations NABL accredited?

Yes. Our Energy - Gauss - pH - Conductivity laboratory is accredited under ISO/IEC 17025:2017 by NABL (Certificate No: CC-4178), ensuring global acceptance and unbroken traceability to NPL/NIST primary standards.

Do you offer on-site Energy - Gauss - pH - Conductivity calibration at client plants?

Yes, Reva Calibration Laboratories deploys mobile metrology teams across Chennai, Tamil Nadu, and PAN-India industrial hubs for on-site Energy - Gauss - pH - Conductivity calibration, minimizing equipment downtime.

What is the standard turnaround time for calibration certificates?

Standard turnaround time is 3 to 5 working days for permanent laboratory orders. Express same-day and next-day calibration slots are available upon prior request.