Torque - Generating Device, Wrench Calibration Services
Torque Wrench, Torque Screw Driver, Torque Spanner, Torque Gauge (Type I & II), Hydraulic Torque Wrench, Electric Torque Wrench, Pneumatic Torque Wrench, Impact Torque Tool, Rotary Torque Tool, Torque Controlled DC Nut Runner.
Instruments & Parameters Covered (10)
Search or review approved measurement ranges and Calibration & Measurement Capabilities (CMC).
| Instrument / Parameter | Calibration Range | CMC (±) | Master / Method |
|---|---|---|---|
| Torque Wrench, Torque Screw Driver, Torque Spanner (50 Nm to 200 Nm) | > 50 Nm to 200 Nm | 0.75 % rdg | Using Torque Transducer with Indicator, Torque Wrench Tester by Comparison Method as per ISO 6789-1:2017, ISO 6789-2:2017 |
| Torque Wrench, Torque Screw Driver, Torque Spanner (5 Nm to 50 Nm) | 5 Nm to 50 Nm | 1 % rdg | Using Torque Transducer with Indicator, Torque Wrench Tester by Comparison Method as per ISO 6789-1:2017, ISO 6789-2:2017 |
| Torque Wrench, Torque Screw Driver, Torque Spanner, Torque Gauge (2 Nm to 10 Nm) | > 2 Nm to 10 Nm | 1.46 % rdg | Using Torque Transducer with Indicator, Torque Wrench Tester by Comparison Method as per ISO 6789-1:2017, ISO 6789-2:2017 |
| Torque Wrench, Torque Screw Driver, Torque Spanner, Torque Gauge (0.01 Nm to 2 Nm) | 0.01 Nm to 2 Nm | 0.6 % rdg | Using Torque Transducer with Indicator, Torque Wrench Tester by Comparison Method as per ISO 6789-1:2017, ISO 6789-2:2017 |
| Torque Wrench, Torque Spanner (1000 Nm to 3000 Nm) | > 1000 Nm to 3000 Nm | 0.84 % rdg | Using Torque Transducer with Indicator, Torque Wrench Tester by Comparison Method as per ISO 6789-1:2017, ISO 6789-2:2017 |
| Torque Wrench, Torque Spanner (200 Nm to 1000 Nm) | > 200 Nm to 1000 Nm | 0.47 % rdg | Using Torque Transducer with Indicator, Torque Wrench Tester by Comparison Method as per ISO 6789-1:2017, ISO 6789-2:2017 |
| Hydraulic, Electric & Pneumatic Torque Wrenches | 0.5 kNm to 1,00,000 kNm | 0.20% | Using Hydraulic Torque Wrench Calibrator with Torque Sensor & Digital Torque Indicator by Comparison Method as per ISO 5393:2017 |
| Impact Torque Tool | 5 Nm to 2000 Nm | 0.35% | Using Torque Calibration System and Torque Sensor With Digital Indicator by Comparison Method as per ISO/TS 17104: 2006 |
| Pneumatic, Electrical & Hydraulic Torque Tools | 0.5 Nm to 2000 Nm | 0.14% | Using Torque Calibration System and Torque Sensor with Digital Indicator by Comparison Method as per ISO 5393: 2017 |
| Rotary Torque Tool / Torque Controlled DC Nut Runner | 0.5 Nm to 2000 Nm | 0.14% | Using Torque Calibration System and Torque Sensor with Digital Indicator by Comparison Method as per ISO 5393: 2017 |
Frequently Asked Questions
Are Torque - Generating Device, Wrench calibrations NABL accredited?
Yes. Our Torque - Generating Device, Wrench laboratory is accredited under ISO/IEC 17025:2017 by NABL (Certificate No: CC-4178), ensuring global acceptance and unbroken traceability to NPL/NIST primary standards.
Do you offer on-site Torque - Generating Device, Wrench calibration at client plants?
Yes, Reva Calibration Laboratories deploys mobile metrology teams across Chennai, Tamil Nadu, and PAN-India industrial hubs for on-site Torque - Generating Device, Wrench calibration, minimizing equipment downtime.
What is the standard turnaround time for calibration certificates?
Standard turnaround time is 3 to 5 working days for permanent laboratory orders. Express same-day and next-day calibration slots are available upon prior request.
How do I request a quotation for Torque - Generating Device, Wrench?
Click the "Request a Quote" button on this page to pre-select Torque - Generating Device, Wrench, upload your instrument list (up to 15 MB PDF/Excel), or call +91 98406 72352 for immediate scope verification.