Optical - Photometry - Radiometry Calibration Services
Illuminance (Lux) Meters, Luminance Meters, Luminous Intensity & Flux, Specular Gloss Meters & Tiles (20°, 60°, 85°), UV Radiometers (UVA, UVB, UVC) & UV Lamps/LEDs.
Instruments & Parameters Covered (36)
Search or review approved measurement ranges and Calibration & Measurement Capabilities (CMC).
| Instrument / Parameter | Calibration Range | CMC (±) | Master / Method |
|---|---|---|---|
| Illuminance Meter [> 1000 lx to 50000 lx] | > 1000 lx to 50000 lx | 2.7 % | Using V - Lambda and Cosine Corrected Photometer (Detector based Photometry), DC Power Supply by Comparison Method |
| Illuminance Meter [> 50000 lx to 200000 lx] | > 50000 lx to 200000 lx | 2.65 % | Using V - Lambda and Cosine Corrected Photometer (Detector based Photometry), DC Power Supply by Comparison Method |
| Illuminance Meter [0.1 lx to 1000 lx] | 0.1 lx to 1000 lx | 2.55 % | Using V - Lambda and Cosine Corrected Photometer (Detector based Photometry), DC Power Supply by Comparison Method |
| Illuminance Meter [> 1000 lx to 50000 lx] | > 1000 lx to 50000 lx | 2.7 % | Using Standard Lamp by Direct Method |
| Illuminance Meter [> 50000 lx to 200000 lx] | > 50000 lx to 200000 lx | 2.65 % | Using Standard Lamp by Direct Method |
| Illuminance Meter [0.1 lx to 1000 lx] | 0.1 lx to 1000 lx | 2.55 % | Using Standard Lamp by Direct Method |
| Luminous Intensity of Light Source [1 cd to 1200 cd] | 1 cd to 1200 cd | 1.82 % | Using V - Lambda and Cosine Corrected Photometer (Detector based Photometry), DC Power Supply by Comparison Method |
| Luminance meter [1 cd/m2 to 1000 cd/m2] | 1 cd/m2 to 1000 cd/m2 | 2.55 % | Using Standard Luminous Intensity Lamp and V - Lambda & Cosine corrected Photometer (Detector based Photometry) by Comparison Method |
| Luminance meter [> 1000 cd/m2 to 50000 cd/m2] | > 1000 cd/m2 to 50000 cd/m2 | 2.70 % | Using Standard Luminous Intensity Lamp and V - Lambda & Cosine corrected Photometer (Detector based Photometry) by Comparison Method |
| Luminance meter [> 50000 cd/m2 to 200000 cd/m2] | > 50000 cd/m2 to 200000 cd/m2 | 2.65 % | Using V - Lambda and Cosine Corrected Photometer (Detector based Photometry), DC Power Supply by Comparison Method |
| Specular Gloss Meter [0 to 100 GU] | 0 to 100 GU | 0.6 GU | Using Gloss Reference Standard by Direct Method as per ASTM D23-08 & ISO 2813 |
| Specular Gloss Meter [100 to 2000 GU] | 100 to 2000 GU | 18.5 GU | Using Gloss Reference Standard by Direct Method as per ASTM D23-08 & ISO 2813 |
| Specular Gloss Meter [0 to 100 GU] | 0 to 100 GU | 0.6 GU | Using Reference Gloss Meter By Comparison Method as per ASTM D23-08 & ISO 2813 |
| Specular Gloss Meter [100 to 2000 GU] | 100 to 2000 GU | 18.5 GU | Using Reference Gloss Meter By Comparison Method as per ASTM D23-08 & ISO 2813 |
| Specular Gloss Tile [0 to 100 GU] | 0 to 100 GU | 0.6 GU | Using Reference Gloss Meter By Comparison method |
| Specular Gloss Tile [100 to 2000 GU] | 100 to 2000 GU | 18.5 GU | Using Reference Gloss Meter By Comparison method |
| Specular Gloss Tile [0 to 100 GU] | 0 to 100 GU | 0.6 GU | Using Reference Gloss Meter By Comparison method |
| Specular Gloss Tile [100 to 2000 GU] | 100 to 2000 GU | 18.5 GU | Using Reference Gloss Meter By Comparison method |
| Specular Gloss Tile [0 to 100 GU] | 0 to 100 GU | 0.6 GU | Using Reference Gloss Meter By Comparison method |
| Specular Gloss Tile [100 to 2000 GU] | 100 to 2000 GU | 18.5 GU | Using Reference Gloss Meter By Comparison method |
| Radiometer / UV Meter / UV Detector (Irradiance) [0.1 to 500 µW/cm²] | 0.1 to 500 µW/cm² | 2.9 % | Using Standard Lamp, UV Detector, Radiometer & Picoammeter by Comparison Method |
| Radiometer / UV Meter / UV Detector (Irradiance) [500 to 2000 µW/cm²] | 500 to 2000 µW/cm² | 2.85 % | Using Standard Lamp, UV Detector, Radiometer & Picoammeter by Comparison Method |
| Radiometer / UV Meter / UV Detector (Irradiance) [2000 to 20000 µW/cm²] | 2000 to 20000 µW/cm² | 2.85 % | Using Standard Lamp, UV Detector, Radiometer & Picoammeter by Comparison Method |
| Radiometer / UV Meter / UV Detector (Irradiance) [0.1 to 500 µW/cm²] | 0.1 to 500 µW/cm² | 2.9 % | Using Standard Lamp by Direct Method |
| Radiometer / UV Meter / UV Detector (Irradiance) [500 to 2000 µW/cm²] | 500 to 2000 µW/cm² | 2.85 % | Using Standard Lamp by Direct Method |
Frequently Asked Questions
Are Optical - Photometry - Radiometry calibrations NABL accredited?
Yes. Our Optical - Photometry - Radiometry laboratory is accredited under ISO/IEC 17025:2017 by NABL (Certificate No: CC-4178), ensuring global acceptance and unbroken traceability to NPL/NIST primary standards.
Do you offer on-site Optical - Photometry - Radiometry calibration at client plants?
Yes, Reva Calibration Laboratories deploys mobile metrology teams across Chennai, Tamil Nadu, and PAN-India industrial hubs for on-site Optical - Photometry - Radiometry calibration, minimizing equipment downtime.
What is the standard turnaround time for calibration certificates?
Standard turnaround time is 3 to 5 working days for permanent laboratory orders. Express same-day and next-day calibration slots are available upon prior request.
How do I request a quotation for Optical - Photometry - Radiometry?
Click the "Request a Quote" button on this page to pre-select Optical - Photometry - Radiometry, upload your instrument list (up to 15 MB PDF/Excel), or call +91 98406 72352 for immediate scope verification.