Skip to main content
NABL Accredited ISO/IEC 17025:2017 • CC-4178 Permanent Lab Calibration + On-Site Field Calibration 269 Scopes

Temperature & Relative Humidity Calibration Services

Contact Temperature (-196°C to 1500°C), Relative Humidity (10% to 95% RH), Dew Point (-20°C to 20°C), and Thermal & Environmental Chambers (Single & Multi-Position).

WhatsApp Lab Desk
Calibration Capability (CMC)
Temperature: ± 0.04°C to 0.14°C (-196°C to 650°C) | High Temp: ± 1.5°C to 3.2°C (600°C to 1500°C) | Humidity: ± 1.27% to 1.6% RH (10% to 95% RH) | Dew Point: ± 0.78°C to 0.85°C (-20°C to 20°C).
Primary Master Equipment
Standard Platinum Resistance Thermometer (SSPRT), S-Type & R-Type Thermocouples with Indicators, PRT Probes, 6½ Digit Multimeters, Precision Liquid Baths, Dry Block Calibrators, Liquid Nitrogen LN2 Apparatus, Humidity Chambers & Dew Point Meters.
Governing Standards
ITS-90, ASTM E220, ASTM E77, IEC 60751, IEC 60068-3-5, EURAMET cg-8, ISO/IEC 17025:2017.
Key Parameters & Applications
Cryogenic to ultra-high temperature (-196°C to 1500°C), Relative Humidity (10% to 95% RH @ 10°C to 60°C), Dew point (-20°C to 20°C), Multi-point and single-position chamber profiling.

Instruments & Parameters Covered (269)

Search or review approved measurement ranges and Calibration & Measurement Capabilities (CMC).

Instrument / Parameter Calibration Range CMC (±) Master / Method
Analog/Digital-Hygrometer @ 50% RH [Permanent] (5 °C to 60 °C) 5 °C to 60 °C 0.15 °C Using Temperature & Humidity Indicator with Sensor, PRT Sensor with Precision Multimeter and Temperature & Humidity Generator by Comparison Method
Temperature & Humidity Indicator with Sensor/Probe @ 50% RH [Permanent] (5 °C to 60 °C) 5 °C to 60 °C 0.15 °C Using Temperature & Humidity Indicator with Sensor, PRT Sensor with Precision Multimeter and Temperature & Humidity Generator by Comparison Method
Thermo Hygrogaph @ 50% RH [Permanent] (5 °C to 60 °C) 5 °C to 60 °C 0.15 °C Using Temperature & Humidity Indicator with Sensor, PRT Sensor with Precision Multimeter and Temperature & Humidity Generator by Comparison Method
Humidity Transmitter with/without Indicator @ 50% RH [Permanent] (5 °C to 60 °C) 5 °C to 60 °C 0.15 °C Using Temperature & Humidity Indicator with Sensor, PRT Sensor with Precision Multimeter and Temperature & Humidity Generator by Comparison Method
Data Logger with Sensor @ 50% RH [Permanent] (5 °C to 60 °C) 5 °C to 60 °C 0.15 °C Using Temperature & Humidity Indicator with Sensor, PRT Sensor with Precision Multimeter and Temperature & Humidity Generator by Comparison Method
Weather Monitoring system @ 50% RH [Permanent] (5 °C to 60 °C) 5 °C to 60 °C 0.15 °C Using Temperature & Humidity Indicator with Sensor, PRT Sensor with Precision Multimeter and Temperature & Humidity Generator by Comparison Method
Analog/Digital-Hygrometer @ 10 °C to 60 °C [Permanent] (10 %RH to 95 %RH) 10 %RH to 95 %RH 1.27 %RH Using Temperature & Humidity Indicator with Sensor and Temperature & Humidity Generator by Comparison Method
Temperature & Humidity Indicator with Sensor/Probe @ 10 °C to 60 °C [Permanent] (10 %RH to 95 %RH) 10 %RH to 95 %RH 1.27 %RH Using Temperature & Humidity Indicator with Sensor and Temperature & Humidity Generator by Comparison Method
Thermohygrogaph @ 10 °C to 60 °C [Permanent] (10 %RH to 95 %RH) 10 %RH to 95 %RH 1.27 %RH Using Temperature & Humidity Indicator with Sensor and Temperature & Humidity Generator by Comparison Method
Humidity Transmitter with/without Indicator @ 10 °C to 60 °C [Permanent] (10 %RH to 95 %RH) 10 %RH to 95 %RH 1.27 %RH Using Temperature & Humidity Indicator with Sensor and Temperature & Humidity Generator by Comparison Method
Data Logger with Sensor @ 10 °C to 60 °C [Permanent] (10 %RH to 95 %RH) 10 %RH to 95 %RH 1.27 %RH Using Temperature & Humidity Indicator with Sensor and Temperature & Humidity Generator by Comparison Method
Weather Monitoring system @ 10 °C to 60 °C [Permanent] (10 %RH to 95 %RH) 10 %RH to 95 %RH 1.27 %RH Using Temperature & Humidity Indicator with Sensor and Temperature & Humidity Generator by Comparison Method
Dew Point Meter @ 10 %RH to 95 %RH [Permanent] ((-) 20 °C to 20 °C) (-) 20 °C to 20 °C 0.78 °C Using Digital Temperature & Humidity Dew Point Meter and Humidity Chamber by Comparison method
Dew Point Temperature Meter @ 10 %RH to 95 %RH [Permanent] ((-) 20 °C to 20 °C) (-) 20 °C to 20 °C 0.78 °C Using Digital Temperature & Humidity Dew Point Meter and Humidity Chamber by Comparison method
Dew Point Temperature Indicator with sensor @ 10 %RH to 95 %RH [Permanent] ((-) 20 °C to 20 °C) (-) 20 °C to 20 °C 0.78 °C Using Digital Temperature & Humidity Dew Point Meter and Humidity Chamber by Comparison method
Dew point Transmitter @ 10 %RH to 95 %RH [Permanent] ((-) 20 °C to 20 °C) (-) 20 °C to 20 °C 0.78 °C Using Digital Temperature & Humidity Dew Point Meter and Humidity Chamber by Comparison method
Dew point Sensor / Probe @ 10 %RH to 95 %RH [Permanent] ((-) 20 °C to 20 °C) (-) 20 °C to 20 °C 0.78 °C Using Digital Temperature & Humidity Dew Point Meter and Humidity Chamber by Comparison method
Dew Point Generator @ 10 %RH to 95 %RH [Permanent] ((-) 20 °C to 20 °C) (-) 20 °C to 20 °C 0.85 °C Using Temperature & Humidity Indicator with Sensor by Comparison Method
Humidity Chamber @ 10 %RH to 95 %RH [Permanent] ((-) 20 °C to 20 °C) (-) 20 °C to 20 °C 0.85 °C Using Temperature & Humidity Indicator with Sensor by Comparison Method
Climatic Chamber (Single Position) - @ 10 %RH to 95 %RH [Permanent] ((-) 20 °C to 20 °C) (-) 20 °C to 20 °C 0.85 °C Using Temperature & Humidity Indicator with Sensor by Comparison Method
Humidity Indicator/Controller with Sensor of Environmental Chamber @ 10 °C to 60 °C [Permanent] (10 %RH to 95 %RH) 10 %RH to 95 %RH 1.6 %RH Using Temperature & Humidity Indicator with Sensor by Comparison Method
Humidity/Climatic Chamber/Generator @ 10 °C to 60 °C [Permanent] (10 %RH to 95 %RH) 10 %RH to 95 %RH 1.6 %RH Using Temperature & Humidity Indicator with Sensor by Comparison Method
Humidifier @ 10 °C to 60 °C [Permanent] (10 %RH to 95 %RH) 10 %RH to 95 %RH 1.6 %RH Using Temperature & Humidity Indicator with Sensor by Comparison Method
Stability Chamber @ 10 °C to 60 °C [Permanent] (10 %RH to 95 %RH) 10 %RH to 95 %RH 1.6 %RH Using Temperature & Humidity Indicator with Sensor by Comparison Method
Salt Spray Chamber @ 10 °C to 60 °C [Permanent] (10 %RH to 95 %RH) 10 %RH to 95 %RH 1.6 %RH Using Temperature & Humidity Indicator with Sensor by Comparison Method

Frequently Asked Questions

Are Temperature & Relative Humidity calibrations NABL accredited?

Yes. Our Temperature & Relative Humidity laboratory is accredited under ISO/IEC 17025:2017 by NABL (Certificate No: CC-4178), ensuring global acceptance and unbroken traceability to NPL/NIST primary standards.

Do you offer on-site Temperature & Relative Humidity calibration at client plants?

Yes, Reva Calibration Laboratories deploys mobile metrology teams across Chennai, Tamil Nadu, and PAN-India industrial hubs for on-site Temperature & Relative Humidity calibration, minimizing equipment downtime.

What is the standard turnaround time for calibration certificates?

Standard turnaround time is 3 to 5 working days for permanent laboratory orders. Express same-day and next-day calibration slots are available upon prior request.

How do I request a quotation for Temperature & Relative Humidity?

Click the "Request a Quote" button on this page to pre-select Temperature & Relative Humidity, upload your instrument list (up to 15 MB PDF/Excel), or call +91 98406 72352 for immediate scope verification.

Explore Related Calibration Disciplines & Services

Industrial Turnkey AMC Plans • NABL Lab Setup Consultancy • ISO/IEC 17025:2017 Training Courses • Direct Lab Helpdesk
Call Lab WhatsApp