Thermal - Contact - Non-Contact Calibration Services

Infrared Thermometers, Non-Contact Thermometers, Pyrometers, Thermal Imaging Cameras (-20°C to 1700°C), Black Body Sources & Cavities (-20°C to 1700°C), and Contact Dry Block Calibrators / Temperature Baths (650°C to 1500°C).

WhatsApp Lab Desk
Calibration Capability (CMC)
Non-Contact Temperature: ± 1.55°C to 4.12°C (-20°C to 1700°C) | Black Body Source / Cavity: ± 1.8°C to 4.12°C (-20°C to 1700°C) | Contact Dry Block Bath: ± 1.56°C to 2.1°C (650°C to 1500°C).
Primary Master Equipment
Black Body Sources, Spherical Cavity Black Body Furnaces, Standard Optical Transfer Pyrometers, Reference IR Thermometers, S-Type Master Thermocouple with Digital Indicator.
Governing Standards
ASTM E2847, ASTM E1862, IEC TS 62492, VDI/VDE 3511, EURAMET cg-20, ASTM E220, ISO/IEC 17025:2017.
Key Parameters & Applications
Radiation temperature, effective emissivity (0.95 & 0.99), cavity uniformity, field of view D:S ratio, thermal imaging camera calibration, dry block comparison (650°C to 1500°C).

Instruments & Parameters Covered (76)

Search or review approved measurement ranges and Calibration & Measurement Capabilities (CMC).

Instrument / Parameter Calibration Range CMC (±) Master / Method
IR Thermometer [Permanent] (50 °C to 100 °C) 50 °C to 100 °C 1.55 °C Using IR Thermometer and Black Body Source by Comparison Method
IR Thermometer [Permanent] (> 100 °C to 500 °C) > 100 °C to 500 °C 1.8 °C Using IR Thermometer and Black Body Source by Comparison Method
Non-Contact Thermometer [Permanent] (50 °C to 100 °C) 50 °C to 100 °C 1.55 °C Using IR Thermometer and Black Body Source by Comparison Method
Non-Contact Thermometer [Permanent] (> 100 °C to 500 °C) > 100 °C to 500 °C 1.8 °C Using IR Thermometer and Black Body Source by Comparison Method
Pyrometer [Permanent] (50 °C to 100 °C) 50 °C to 100 °C 1.55 °C Using IR Thermometer and Black Body Source by Comparison Method
Pyrometer [Permanent] (> 100 °C to 500 °C) > 100 °C to 500 °C 1.8 °C Using IR Thermometer and Black Body Source by Comparison Method
Thermal Imaging Camera (Only Temperature) (Emissivity : 0.95) [Permanent] (50 °C to 100 °C) 50 °C to 100 °C 1.55 °C Using IR Thermometer and Black Body Source by Comparison Method
Thermal Imaging Camera (Only Temperature) (Emissivity : 0.95) [Permanent] (> 100 °C to 500 °C) > 100 °C to 500 °C 1.8 °C Using IR Thermometer and Black Body Source by Comparison Method
IR Thermometer [Permanent] (50 °C to 100 °C) 50 °C to 100 °C 2.22 °C Using Pyrometer with Digital Indicator and Black Body Source by Comparison Method
IR Thermometer [Permanent] (> 100 °C to 500 °C) > 100 °C to 500 °C 3.73 °C Using Pyrometer with Digital Indicator and Black Body Source by Comparison Method
IR Thermometer [Permanent] (500 °C to 950 °C) 500 °C to 950 °C 2.04 °C Using Pyrometer with Digital Indicator and Black Body Source by Comparison Method
IR Thermometer [Permanent] (> 950 °C to 1200 °C) > 950 °C to 1200 °C 2.02 °C Using Pyrometer with Digital Indicator and Black Body Source by Comparison Method
IR Thermometer [Permanent] (> 1200 °C to 1700 °C) > 1200 °C to 1700 °C 4.12 °C Using Pyrometer with Digital Indicator and Black Body Source by Comparison Method
Non-Contact Thermometer [Permanent] (50 °C to 100 °C) 50 °C to 100 °C 2.22 °C Using Pyrometer with Digital Indicator and Black Body Source by Comparison Method
Non-Contact Thermometer [Permanent] (> 100 °C to 500 °C) > 100 °C to 500 °C 3.73 °C Using Pyrometer with Digital Indicator and Black Body Source by Comparison Method
Non-Contact Thermometer [Permanent] (500 °C to 950 °C) 500 °C to 950 °C 2.04 °C Using Pyrometer with Digital Indicator and Black Body Source by Comparison Method
Non-Contact Thermometer [Permanent] (> 950 °C to 1200 °C) > 950 °C to 1200 °C 2.02 °C Using Pyrometer with Digital Indicator and Black Body Source by Comparison Method
Non-Contact Thermometer [Permanent] (> 1200 °C to 1700 °C) > 1200 °C to 1700 °C 4.12 °C Using Pyrometer with Digital Indicator and Black Body Source by Comparison Method
Pyrometer [Permanent] (50 °C to 100 °C) 50 °C to 100 °C 2.22 °C Using Pyrometer with Digital Indicator and Black Body Source by Comparison Method
Pyrometer [Permanent] (> 100 °C to 500 °C) > 100 °C to 500 °C 3.73 °C Using Pyrometer with Digital Indicator and Black Body Source by Comparison Method
Pyrometer [Permanent] (500 °C to 950 °C) 500 °C to 950 °C 2.04 °C Using Pyrometer with Digital Indicator and Black Body Source by Comparison Method
Pyrometer [Permanent] (> 950 °C to 1200 °C) > 950 °C to 1200 °C 2.02 °C Using Pyrometer with Digital Indicator and Black Body Source by Comparison Method
Pyrometer [Permanent] (> 1200 °C to 1700 °C) > 1200 °C to 1700 °C 4.12 °C Using Pyrometer with Digital Indicator and Black Body Source by Comparison Method
Thermal Imaging Camera (Only Temperature) (Emissivity : 0.95) [Permanent] (50 °C to 100 °C) 50 °C to 100 °C 2.22 °C Using Pyrometer with Digital Indicator and Black Body Source by Comparison Method
Thermal Imaging Camera (Only Temperature) (Emissivity : 0.95) [Permanent] (> 100 °C to 500 °C) > 100 °C to 500 °C 3.73 °C Using Pyrometer with Digital Indicator and Black Body Source by Comparison Method

Frequently Asked Questions

Are Thermal - Contact - Non-Contact calibrations NABL accredited?

Yes. Our Thermal - Contact - Non-Contact laboratory is accredited under ISO/IEC 17025:2017 by NABL (Certificate No: CC-4178), ensuring global acceptance and unbroken traceability to NPL/NIST primary standards.

Do you offer on-site Thermal - Contact - Non-Contact calibration at client plants?

Yes, Reva Calibration Laboratories deploys mobile metrology teams across Chennai, Tamil Nadu, and PAN-India industrial hubs for on-site Thermal - Contact - Non-Contact calibration, minimizing equipment downtime.

What is the standard turnaround time for calibration certificates?

Standard turnaround time is 3 to 5 working days for permanent laboratory orders. Express same-day and next-day calibration slots are available upon prior request.

How do I request a quotation for Thermal - Contact - Non-Contact?

Click the "Request a Quote" button on this page to pre-select Thermal - Contact - Non-Contact, upload your instrument list (up to 15 MB PDF/Excel), or call +91 98406 72352 for immediate scope verification.